Surge arrester V20, 2-pole with remote signalling, 550 V

Item no. 5095312 | EAN 4012196162901

550
IP20
Product description

Product description

Surge arrester, type 2

• For surge voltage protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)
• Discharge capacity to 40 kA (8/20) per pole through high-performance varistors
• Modular connectable arrester with cut-off unit and visual status display
• Locking mechanism with vibration protection and voltage keying
• Plastic to UL 94 V-0
• The remote signalling variants (FS) have a potential-free changeover contact for remote signalling

Application: Equipotential bonding in main and sub-distributions.
  • Underwriters Laboratories Inc., USA + CSA, Canada
  • 5-year warranty
  • Communautés Européennes, EC declaration of conformity according to EC directives
  • EurAsian Conformity
  • Protection device to DIN EN 61643-11 or IEC 61643-11
  • Transition from LPZ 1 to LPZ 2
  • Installation electrotechnical expertise
  • Remote signalling
Technical data

Technical data

Approvals UL
Blow-out no
Cable type for surge protection devices Power cable AV
Conductor cross-section, flexible (fine-wire), max. 35 mm²
Conductor cross-section, flexible (fine-wire), max. 2 AWG
Conductor cross-section, flexible (fine-wire), min. 1,5 mm²
Conductor cross-section, flexible (fine-wire), min. 16 AWG
Conductor cross-section, rigid (single-wire/multiwire), max. 35 mm²
Conductor cross-section, rigid (single-wire/multiwire), max. 2 AWG
Conductor cross-section, rigid (single-wire/multiwire), min. 16 AWG
Dimension 550V
Housing material PA UL 94 V-0
Installation type DIN rail 35 mm
Integrated back-up fuse no
Maximum back-up fuse 160 A
Maximum continuous voltage (L-N) 550 V
Maximum continuous voltage AC 550
Maximum discharge current (8/20 μs) 40 kA
Maximum discharge current (8/20 μs) [L-N] 40 kA
Network form Other
Nominal discharge current (8/20 µs) 15 kA
Nominal discharge current (8/20 µs) [L-N] 20 kA
Nominal voltage AC (50/60 Hz) 480 V
Operating temperature, max. 80 °C
Operating temperature, min. -40 °C
Pole number 2
Pole version 2
Protection rating IP20
Remote signalling yes
Response time <25 ns
Short-circuit resistant yes
Signalling on device Visual
SPD to EN 61643-11 Type 2
SPD to IEC 61643-1 Class II
Test class, type 2 yes
TN network form yes
TN-C network form yes
Torque 4 Nm

Dimensions

Minimum distance 1,5 mm

Connectivity options

Arrester surge current (8/20 µs) [total] 80 kA
Conductor cross-section, rigid (single-wire/multiwire), min. 1,5 mm²
Connection cross-section, FM terminals, max. 1,5 mm²
Connection cross-section, FM terminals, max. 16 AWG
Connection cross-section, FM terminals, min. 0,5 mm²
Connection cross-section, FM terminals, min. 21 AWG
FM contacts Changeover
Max. mains-side overcurrent protection 160 A gL/gG
Protection level [L-N] ≤2,4
Residual voltage [L-N] @ 1 kA 1,7 kV
Residual voltage [L-N] @ 5 kA 2,1 kV
Short-circuit resistance for max. mains-side overcurrent protection 50 kA eff
SPD to UL 1449 Type 4
Switching power AC 230 V; 0,5 A
Switching power DC 230 V; 0,1 A / 75 V; 0,5 A
TOV voltage [L-N] ‒ fail safe mode ‒ 120 min. 915 V
TOV voltage [L-N] ‒ withstand mode ‒ 5 s 700 V
All types

All types

Types Pole version Maximum continuous voltage AC Protection rating Item no. Quantity SSU
V20-2+FS-550 2 550 IP20 5095312
1 piece
V20-3+FS-550 3 550 IP20 5095313
1 piece
V20-4+FS-550 4 550 IP20 5095314
1 piece